Published in final edited form as: Anal Biochem. 2020 Apr 13;601:113723. doi: 10.1016/j.ab.2020.113723

Table 5.

The accuracy and intra-day, inter-day precision of wogonosides, apigenin-7-O-glucuronide, and baicalin in the bile and blood matrix.

Analytes QCa Intra-day Inter-day

Accuracy (%) Precision (RSD %) Accuracy (%) Precision (RSD %)

Bile Blood Bile Blood Bile Blood Bile Blood
Wogonoside Low 108.4 99.9 2.0 11.2 105.9 94.4 4.4 6.1
Medium 102.5 99.1 4.3 5.6 104.1 96.3 2.7 7.7
High 99 96.7 8.3 3.1 99.7 94.1 4.0 4.4
Apigenin-7-O-glucuronide Low 107.5 111.1 1.7 2.0 111.4 94.5 3.2 5.2
Medium 113.5 98.7 6.9 12.0 108.0 96.4 4.9 11.0
High 88.1 94.8 4.7 9.2 95.2 93.0 3.0 10.6
Baicalin Low 105.9 99.5 4.7 9.9 104.2 92.9 3.2 7.7
Medium 98.0 94.2 4.8 6.7 102.0 88.5 3.7 10.6
High 95.3 97.1 7.9 6.9 94.0 94.4 4.8 8.3
a

Low, medium, and high were 10.0, 156.0, 2500.0 nM in the bile and 1.56, 25.0, and 2000.0 nM in the blood, respectively.