Skip to main content
. 2022 Jun 29;6(15):3565–3572. doi: 10.1039/D2SE00292B

Figures of merit determined from highest chronoamperometric measurements under continuous visible light irradiation. Additional measurements are available in Table S4 in ESI.

Dyad loading (nmol cm−2) n(H2) (nmol) TON F.E. (%)
NiO|T1-Coa 8.2 5.8 <2 8
NiO|T2R-Coa 7.5 6.9 <2 12
NiO|AM1-Cob 3.0 86 30 16
1.5% Li–NiO|AM1-Cob 0.6 27 45 20
a

Over 4 hours; value corresponding to the amount of H2 measured in the headspace.23

b

Over 2 hours.