Skip to main content
. 2022 Jul 18;9:920013. doi: 10.3389/fcvm.2022.920013

Table 1.

Components of solution.

Cardioplegia Normal Tyrode's solution Normal Tyrode's solution for recording
Composition Manufacturer Concentration (mM) Composition Manufacturer Concentration (mM) Composition Manufacturer Concentration (mM)
NaCl VWR Chemicals 110 NaCl VWR Chemicals 140 NaCl VWR Chemicals 140
CaCl2 Sigma-Aldrich 1.2 CaCl2 Sigma-Aldrich 1.8 CaCl2 Sigma-Aldrich 1.8
KCl Sigma-Aldrich 16 KCl Sigma-Aldrich 6 KCl Sigma-Aldrich 4.5
MgCl2 VWR Chemicals 16 MgCl2 VWR Chemicals 1 MgCl2 VWR Chemicals 1
Glucose Sigma-Aldrich 10 Glucose Sigma-Aldrich 10
HEPES VWR Chemicals 10 HEPES VWR Chemicals 10
BDM Sigma-Aldrich 10
*add NaHCO3 (10mM) to pH 7.4 *add NaOH (10M) to pH 7.4 *add NaOH (10M) to pH 7.4

*The component needs to be added to adjust the pH of the solution.