Skip to main content
. 2022 Jun 12;14(2):101–107. doi: 10.34172/jcvtr.2022.16

Table 3. Echocardiographic and cardiac catheterization parameters at baseline and after PTMC .

Preprocedural Post procedural P Value
Echocardiographic data
MVA by planimetry, cm2 0.94 ± 0.27 1.49 ± 0.39 < 0.001
MVA by PHT, cm2 0.98 ± 0.26 1.56 ± 0.38 < 0.001
Mean PG, mmHg 12.74 ± 6.11 6.12 ± 2.9 < 0.001
RVSP, mmHg 54.78 ± 23.10 44.42 ± 18.50 < 0.001
Cardiac catheterization
Mean PG, mmHg 12.63 ± 6.71 5.87 ± 3.79 < 0.001
SPAP, mmHg 61.74 ± 21.43 49.53 ± 17.19 < 0.001
Mean PAP, mmHg 40.43 ± 12.94 31.66 ± 11.32 < 0.001

Abbreviations: MVA , Mitral valve area; PAP , Pulmonary arterial pressure; PHT , Pressure-half time; PG , pressure gradient; PTMC , Percutaneous mitral commissurotomy; RVSP , Right ventricular systolic pressure; SPAP , Systolic pulmonary arterial pressure.