Statistical evaluation of SICTT using real-time PCR and immunohistochemistry (IHC). Data are presented as percentage

Type Method Sensitivity Specificity Accuracy Prevalence PPV 4 NPV 5 Kappa ( p < 0.0005)
M. bovis 1 Real-time PCR 53.70 100 63.80 78.26 100 37.50 0.34
IHC 53.70 100 63.80 78.26 100 100 0.34
MTC 2 Real-time PCR 100 100 100 8.00 100 100 1.00
IHC 100 100 100 8.00 100 100 1.00
MAP 3 Real-time PCR 60.50 100 78.30 55.00 100 67.40 0.58
IHC 60.50 93.60 75.40 55.00 92.00 65.90 0.52

1 Mycobacterium bovis; 2 Mycobacterium tuberculosis complex; 3 Mycobacterium avium subsp. paratuberculosis; 4 Positive predictive values; and 5 Negative predictive values.