Table 4:

Correlations between different performance metrics for all source control devices. Each Spearman’s rank coefficient (ρ) was calculated based on data from 22 experiments for all source control devices and 18 experiments for cloth masks (cloth face masks, gaiters, and bandanas). A correlogram of the ρ values in shown in Figure S9 in the SI.

Correlation parameter #1 Correlation parameter #2 All source control devices Cloth face masks, gaiters,
and bandanas only
ρ p-value ρ p-value
Cough aerosol
collection efficiency
Exhaled aerosol collection efficiency 0.76 <0.001 0.67 0.003
Filtration efficiency of material 0.69 0.001 0.51 0.032
Airflow resistance of material 0.55 0.009 0.54 0.020
Human subject fit (N95 mode) 0.57 0.005 0.30 0.208
Human subject fit (Class 100 mode) 0.68 <0.001 0.48 0.035
Manikin fit before coughing 0.39 0.076 0.03 0.890
Exhaled aerosol
collection efficiency
Filtration efficiency of material 0.60 0.004 0.54 0.023
Airflow resistance of material 0.51 0.016 0.58 0.012
Human subject fit (N95 mode) 0.60 0.003 0.51 0.024
Human subject fit (Class 100 mode) 0.71 <0.001 0.63 0.003
Manikin fit before breathing 0.72 <0.001 0.68 0.002
Manikin fit before coughing Manikin fit before breathing 0.61 0.003 0.38 0.112
Filtration efficiency of material Airflow resistance of material 0.78 <0.001 0.78 <0.001