Skip to main content
. 2022 Aug 2;12:13218. doi: 10.1038/s41598-022-17636-8

Table 2.

Optimum conditions of removal of CV, MG, Cd(II) and Pb(II).

Run Variables %Removal
A (g) B C (mg L-1) D (min) CV MG Cd(II) Pb(II)
Exa Prb Ec Exa Prb Ec Exa Prb Ec Exa Prb Ec
1 0.19 6 10 22 99.15 99.82 0.67 99.69 99.75 0.06 93.37 94.25 0.88 94.22 95.89 1.67
2 0.19 6 10 22 98.82 99.82 0.510 98.79 99.75 0.96 92.67 94.25 1.58 95.26 95.89 0.63
3 0.19 6 10 22 98.75 99.82 1.07 99.20 99.75 0.55 94.46 94.25 -0.21 93.85 95.89 2.04

aExperimental, bPredicted, cError.