Skip to main content
. 2022 Jul 22;12:943415. doi: 10.3389/fonc.2022.943415

Table 3.

Diagnostic Performances of the CNN model evaluated in slice-based and case-based method.

Parameter Slice-based case-based 1* case-based 2* case-based 3*
Accuracy 90.3% 80.4% 78.0% 81.1%
Specificity 79.0% 40.5% 47.6% 59.5%
Sensitivity 96.2% 100.0% 92.9% 91.8%
Positive predictive value 89.8% 77.3% 78.2% 82.1%
Negative predictive value 91.6% 100.0% 76.9% 78.1%

*case-based 1: As long as one slice is positive, the lesion is classified as malignant;

case-based 2: At least two or more slices are positive, the lesion is classified as malignant; case-based 3: At least three or more slices are positive, the lesion is classified as malignant.