Skip to main content
. 2022 Jul 22;12:907181. doi: 10.3389/fonc.2022.907181

Table 2.

The dose-volume constraints on TPS optimization interface for planning target volume and organs at risk.

PTV/OAR Dose–volume constraints
PTV D95%>5000 cGy
Heart V20<15%
D mean<800 cGy
LAD D mean<3000 cGy
LV D mean<1000 cGy
Ipsilateral Lung V5<60%
V20<25%
V30<15%
D mean<1400 cGy
Lungs V5<60%
V20<20%
V30<10%
D mean<800 cGy
Contralateral Lung V5<60%
D mean<600 cGy
Contralateral Breast D0.1cc<2000 cGy
D mean<500 cGy