Table 6. Determination of lymphocyte cut-offs to differentiate between patients with Covid 19 and healthy controls.
Cut off (/μL) | Area under curve | P | 95% Confidence Interval | Sensitivity % | Specificity % | ||
---|---|---|---|---|---|---|---|
Lower Bound | Upper Bound | ||||||
CD3+ cell counts | 1145.5 | 0.922 | <0.001 | 0.874 | 0.969 | 96 | 84 |
CD4+ cell counts | 688.5 | 0.922 | <0.001 | 0.874 | 0.970 | 96 | 84 |
CD8+ cell counts | 365 | 0.877 | <0.001 | 0.829 | 0.946 | 96 | 80 |
CD20+ cell counts | 104.5 | 0.809 | <0.001 | 0.721 | 0.898 | 96 | 47 |