Skip to main content
. 2021 Feb 10;18:6. doi: 10.18502/fid.v18i6.5649

Table 1.

The mean and standard deviation (SD) of the thickness of the replicas at 12 points in the mesial, distal, buccal, and lingual sections (in micron)

Point Impression
technique
Mean SD Standard
error
Minimum Maximum P-value
Buccal1 Digital 73.19 5.15 1.63 61.17 80.04 0.0001
Conventional 160.89 26.57 8.4 121.75 187.16
Buccal2 Digital 69.25 7.14 2.26 56.58 76.17 0.0001
Conventional 142.78 21.93 6.93 121.57 182.02
Buccal3 Digital 73.39 5.17 1.64 66.09 83.66 0.0001
Conventional 140.69 19.52 6.17 120.31 180.15
Lingual 1 Digital 72.25 14.04 4.44 53.17 87.91 0.0001
Conventional 141.95 21.01 6.64 123.17 178.81
Lingual2 Digital 74.96 8.03 2.54 62.48 88.93 0.0001
Conventional 147.16 22.63 7.16 121.65 184.24
Lingual3 Digital 74.97 8.71 2.75 54.61 84.91 0.0001
Conventional 150.33 26.54 8.39 120.23 187.62
Mesial1 Digital 66.32 8.77 2.77 52.98 83.81 0.0001
Conventional 166.54 19.91 6.29 128.48 187.17
Mesial2 Digital 63.59 10.78 3.41 52.96 86.09 0.0001
Conventional 164.61 21.75 6.88 123.17 184.82
Mesial3 Digital 64.29 10.82 3.42 51.88 82.72 0.0001
Conventional 157.76 25.75 8.14 121.02 188.66
Distal1 Digital 62.03 7.5 2.37 54.61 74.62 0.0001
Conventional 149.76 20.49 6.48 123.26 180.54
Distal2 Digital 58.99 4.59 1.45 54.61 66.23 0.0001
Conventional 164.85 19.35 6.12 127.81 183.18
Distal3 Digital 61.21 10.09 3.19 52.98 81.44 0.0001
Conventional 145.95 21.76 6.88 187.6 122.65