Skip to main content
. 2021 Feb 10;18:6. doi: 10.18502/fid.v18i6.5649

Table 3.

The mean thickness of the replicas at all points in the mesial, distal, buccal, and lingual sections

Point Impression
technique
Mean Standard
deviation
Standard
error
Minimum Maximum P-value
Buccal Digital 71.95 3.23 1.02 64.78 74.96 0.0001
Conventional 148.12 25.0 4.74 129.13 180.73
Lingual Digital 74.04 7.2 2.28 64.62 87.25 0.0001
Conventional 146.48 14.55 4.6 122.61 166.07
Mesial Digital 64.73 8.86 2.8 52.61 84.21 0.0001
Conventional 162.97 19.6 6.19 125.62 183.51
Distal Digital 60.75 5.87 1.86 55.75 70.22 0.0001
Conventional 153.52 16.64 5.26 125.95 174.31