Skip to main content
. 2022 Jul 19;57:101140. doi: 10.1016/j.dcn.2022.101140

Table 6.

Statistics for the performance of various artifact rejection methods on trial retention after segment rejection using HAPPE’s amplitude threshold criteria (−150 to 150 mV).

Mean Standard Deviation Range Mean Standard Deviation Range
Clean
Raw Data 55.88 5.10 40–60 93.13 8.50 66.67–100.00
Wavelet Thresholding 59.13 2.39 51–60 98.54 3.98 85.00–100.00
ICA with MARA.5 59.75 0.58 58–60 99.58 0.96 96.67–100.00
ICA with iMARA.2 56.38 4.92 40–60 93.96 8.21 66.67–100.00
ICA with ICLabel.8 57.75 3.04 49–60 96.25 5.07 81.67–100.00
ICA with Hand Rejection 59.25 1.13 56–60 98.75 1.88 93.33–100.00
Artifact-Added
Raw Data 48.19 7.12 31–57 80.31 11.87 51.67–95.00
Wavelet Thresholding 55.81 4.61 45–60 93.02 7.68 75.00–100.00
ICA with MARA.5 59.38 1.31 55–60 98.96 2.18 91.67–100.00
ICA with iMARA.2 50.06 7.51 32–100 83.44 12.51 53.33–100.00
ICA with ICLabel.8 51.00 6.60 32–58 85.00 11.01 53.33–96.67
ICA with Hand Rejection 58.25 1.61 54–60 97.08 2.69 90.00–100.00