Table 3.
Aortic diameters before and after reduction ascending aortoplasty, measured in mm by computed tomography.
| Preoperative aortic diameter [n = 241 (100%)] | |
|---|---|
| mean (±SD) | 44.7 (3.5) |
| Max. diameter | 56 |
| 40 ≤ 45, n = (%) | 105 (43.6) |
| 45 ≤ 50, n = (%) | 97 (40.2) |
| 50 ≤ 55, n = (%) | 23 (9.5) |
| >55, n = (%) | 1 (0.4) |
| Postoperative aortic diameter [n = 87 (100%)] | |
| Highest, mean (±SD) | 40.6 (5.8) |
| Last, mean (±SD) | 40.2 (5.7) |
| Max. diameter | 70 |
| 40 ≤ 45, n = (%) | 32 (36.8) |
| 45 ≤ 50, n = (%) | 12 (13.8) |
| >50, n = (%) | 5 (5.7) |
Mean diameter is stated for the highest measured diameters (Highest) and the last (Last) in each patient follow-up.