Skip to main content
. Author manuscript; available in PMC: 2022 Aug 9.
Published in final edited form as: J Aerosol Sci. 2021 May;154:1–16. doi: 10.1016/j.jaerosci.2020.105734

Table 3.

Experimental test matrix for VARIAnT 1 and 2.

Test Campaign Test ID Date Source Tested Run Conditionsa
VARIAnT 1 CAST 1 09/04/14 Mini-CAST Shake down
CAST 2 09/05/14 Mini-CAST Probe switching
CAST 3 09/05/14 Mini-CAST Probe switching
CAST 4 09/05/14 Mini-CAST Probe switching
CAST 5 09/06/14 Mini-CAST Calibration of semi-continuous OCEC
CAST 6 09/06/14 Mini-CAST Calibration of semi-continuous OCEC
CAST 7 09/07/14 Mini-CAST Varying sampling system operating parameters
Engine 1 09/08/14 J85 w/Jet-A Probe switching at 15, 40, 60, 80, and 90 PLA
Engine 2 09/09/14 J85 w/Jet-A Baseline sampling at 15, 40, 60, and 80 PLA
Engine 3 09/10/14 J85 w/100% Camelina Baseline sampling at 50 and 90 PLA
Engine 4 09/12/14 J85 w/Jet-A Varying diluent at 15, 50, and 90 PLA
Engine 5 09/13/14 J85 w/Jet-A Varying sampling system operating parameters at 15, 60, and 90 PLA
Engine 6 09/14/14 J85 w/Jet-A Varying sampling system operating parameters at 15, 40, and 90 PLA
Engine 7 09/15/14 J85 w/91% Camelina blend Baseline sampling at 45 and 90 PLA
Engine 8 09/15/14 J85 w/50% Camelina blend Varying sampling system operating parameters at 90 PLA
Engine 9 09/16/14 J85 w/50% Camelina blend Varying sampling system operating parameters at 90 PLA
Engine 10 09/16/14 J85 w/50% Camelina blend Single probe w/2-way splitter providing sample to the two systems at 15, 60, and 90 PLA
CAST 8 09/17/14 Mini-CAST Different CAST settings
VARIAnT 2 IC1 08/21/15 Mini-CAST Instrument comparison of PM instruments on same source with multiple CAST settings
C2 08/23/15 Mini-CAST Probe and line switching with multiple CAST settings
C3 08/24/15 Mini-CAST Comparison to EC reference method at various concentrations
C4 08/24/15 Mini-CAST Intra-system instrument comparison at different concentrations
E1 08/25/15 J85 w/Jet-A Probe switching by rake movement at 15, 60, and 90 PLA
E2 08/26/15 J85 w/Jet-A Comparison to EC reference method at 15, 60, and 90 PLA
E3 08/29/15 J85 w/50% Camelina blend Intra-system instrument comparison at 15, 60, and 90 PLA plus probe switching at 15, 20, 30, 40, 50, 60, 70, 80, and 90 PLA
E4 08/27/15 J85 w/50% Camelina blend and J85 w/Jet-A Intra-system instrument comparison at 15, 60, and 90 PLA using Camelina blend plus intra-system instrument comparison at 90 PLA using Jet-A
E5 08/28/15 J85 w/Jet-A Comparison to EC reference method at 15, 60, and 90 PLA
IC2 08/30/15 Mini-CAST Instrument comparison of PM instruments on same source (used to adjust BC instrument calibration constants)
C6 08/30/15 Mini-CAST Comparison to EC reference method at various concentrations
a