Skip to main content
. 2022 May 12;12(9):2132–2144. doi: 10.1007/s13346-022-01159-w

Table 2.

Model parameter chosen to be optimized, as well as their upper and lower limits used in the MCMC method

Parameter (unit) Upper/lower limits
(PACA-Cbz
Upper/lower limits (LipImage™ 815) Description
χrich (-) 1.67 × 10−2–15 1.67 × 10−1–150 Permeability of richly perfused organs
P (-) 3.3 × 10−2–30 1.67 × 10−3–1.5 Tissue-blood partition coefficient
kkidneyEl (h−1) 1–900 3.3 × 10−2–30 Renal elimination rate
kab0 (h−1) 1.16 × 10−2–10.5 3.3 × 10−2–30 The maximum uptake rate of phagocytizing cells in organs except for the spleen
ksab0 (h−1) 1.67 × 10−2–15 3.3 × 10−2–30 The maximum uptake rate of phagocytizing cells in the spleen
kde (h−1) 3.3 × 10−5–0.03 3.3 × 10−5–0.03 The release rate of phagocytizing cells