Modality Complexity Dimensions Accuracy
(%)
Sensitivity
(%)
Specificity
(%)
Single Modality Models CBV 5 93.7 ± 1.9 71.5 ± 8.7 100 ± 0
Cho/Cr 5 93.3 ± 5.0 69.8 ± 22.6 100 ± 0
ΔT2 5 90.9 ± 2.7 59.0 ± 12.1 100 ± 0
ΔT1 5 88.2 ± 4.0 46.8 ± 18.0 100 ± 0
Cho/NAA 5 88.0 ± 3.9 37.0 ± 17.6 100 ± 0
NAA/Cr 5 86.8 ± 2.9 40.8 ± 13.1 100 ± 0
FA 5 86.5 ± 4.1 39.3 ± 18.6 100 ± 0
ADC 5 83.8 ± 3.1 35.0 ± 12.3 100 ± 0
T2 5 81.4 ± 3.5 16.5 ± 15.6 100 ± 0
CE T1 5 80.6 ± 3.3 12.5 ± 14.9 100 ± 0
T1 5 80.4 ± 3.0 12.0 ± 13.5 100 ± 0
Combination Models Top 2 (CBV, Cho/Cr) 10 93.5 ± 2.1 70.8 ± 9.4 100 ± 0
Top 3 (CBV, Cho/Cr, ΔT2) 15 92.1 ± 2.9 64.5 ± 12.9 100 ± 0
All 55 91.8 ± 2.8 63.0 ± 12.6 100 ± 0
DWI (ADC, FA) 10 88.9 ± 4.7 55.5 ± 18.7 100 ± 0
MRS (Cho/Cr, Cho/NAA, NAA/Cr) 15 85.8 ± 3.3 43.0 ± 13.3 100 ± 0
SUBTRACTION (ΔT1, ΔT2) 10 89.4 ± 4.0 52.3 ± 18.2 100 ± 0

All the data represents mean ± standard deviation unless otherwise indicated. Abbreviations: ADC, Apparent Diffusion Coefficeint; CBV, Cerebral Blood Volume; Cho, Choline; NAA, N-acetylaspartate; Cr, Creatine; FA, fractional anisotropy; CE, Contrast Enhanced; DWI, diffusion-weighted imaging; MRS, MR spectroscopy