. 2022 Jul 27;12:892923. doi: 10.3389/fonc.2022.892923

Table 3.

Dose exposure for the complete radiotherapy regime as shown in Figure 6 .

scenario 1 scenario 2 scenario 3 scenario 4
organ at risk breast size IMRT + brachytherapy IMRT + SiB 3D-CRT + brachytherapy 3D-CRT + sequential boost
heart small 1.1 ± 0.3
(0.9–1.6)
1.7 ± 0.4
(1.2–2.2)
0.6 ± 0.2
(0.6–0.9)
1.9 ± 0.7
(0.7–2.6)
large 3.1 ± 2.8
(1.6–7.8)
1.2 ± 0.4
(0.8–1.9)
1.4 ± 0.5
(1.0–2.1)
1.3 ± 0.5
(0.9–2.0)
left lung
(ipsilateral)
small 3.3 ± 2.4
(1.0–7.1)
2.3 ± 1.4
(0.7–3.6)
1.0 ± 0.7
(0.4–2.1)
1.5 ± 1.5
(0.4–4.0)
large 18.8 ± 13.9
(7.8–38.3)
10.4 ± 18.3
(1.1–43.0)
12.8 ± 17.2
(1.0–41.5)
12.7 ± 17.1
(1.0–41.2)
right lung
(contralateral)
small 0.4 ± 0.1
(0.3–0.5)
0.5 ± 0.2
(0.3–0.8)
0.2 ± 0.1
(0.2–0.3)
0.5 ± 0.4
(0.3–1.2)
large 0.6 ± 0.1
(0.5–0.6)
0.4 ± 0.1
(0.3–0.4)
0.4 ± 0.1
(0.3–0.4)
0.4 ± 0.1
(0.3–0.4)
right breast
(contralateral)
small 1.6 ± 0.6
(1.0–2.3)
1.7 ± 0.8
(0.9–2.7)
1.7 ± 0.6
(1.2–2.7)
2.4 ± 1.1
(1.3–3.8)
large 1.2 ± 1.0
(0.2–2.8)
1.0 ± 0.7
(0.2–2.0)
1.0 ± 0.7
(0.1–2.0)
1.2 ± 1.1
(0.2–3.0)

All TLD measurement values are given for the small and large breasts [in (Gy)].