Skip to main content
. 2022 Jul 27;11(15):4371. doi: 10.3390/jcm11154371

Table 5.

Statistical analysis of diagnostic efficiency of each index of MSIS and MARS MRI in PJI.

Variable PJI Non-PJI Sensitivity p-Value a (VS. MARS) Specificity p-Value a (VS. MARS) Youden’s Index PPV NPV LR+ LR−
MARS MRI 25/31 5/20 80.65% N/A 75% N/A 0.556 83.33% 71.43% 3.226 0.258
Culture 23/31 5/20 74.19% 0.727 75% 1.000 0.642 92% 69.23% 7.419 0.287
Pre-OP culture 10/31 3/20 32.26% 0.001 85% 0.625 0.173 76.92% 44.74% 2.151 0.797
Intra-OP culture 21/31 2/20 67.74% 0.344 90% 0.453 0.577 91.30% 64.29% 6.774 0.358
CRP (>10 mg/L) 26/31 2/20 83.87% 1.000 90% 0.375 0.739 92.86% 78.26% 8.387 0.179
ESR (>30 mm/h) 25/31 8/20 80.65% 1.000 60% 0.180 0.406 75.76% 66.67% 2.016 0.323
SF-WBC (>3000 × 106/L) 23/31 1/20 74.19% 0.687 95% 0.125 0.692 95.83% 70.37% 14.84 0.272
SF-PMN% (>80%) 19/31 0/20 61.30% 0.109 100% N/A 0.613 100% 62.50% N/A 0.387
Bone destruction+ Lamellated synovitis 26/31 7/20 83.87% - 65% - 0.489 78.79% 72.22% 2.396 0.248
Bone destruction+ Extracapsular edema 28/31 9/20 90.32% - 55% - 0.453 75.68% 78.57% 2.007 0.176
Lamellated synovitis+ Extracapsular edema 29/31 10/20 93.55% - 50% - 0.435 74.36% 83.33% 1.871 0.129

a McNemar’s test; Youden’ s index = sensitivity + specificity − 1; MARS: Metal artifact reduction sequence, PJI: Prosthetic joint infection, LR+: Positive likelihood ratio, LR−: Negative likelihood ratio, NPV: Negative predictive value, PPV: Positive predictive value, N/A: Not applicable, SF-WBC: Synovial fluid white blood cell, SF-PMN: Synovial fluid polymorphonuclear, OP: operative.