Table 13.
Ratio and phase errors of LPVT in harmonics and interharmonic measurements.
| Harmonics | Interharmonics | |||
|---|---|---|---|---|
|
(%) |
(rad) |
(%) |
(rad) |
|
| Test Point 1 | −1.42 | 0.026 | −0.85 | 0.01 |
| Test Point 2 | −2.20 | 0.056 | −3.55 | 0.18 |
| Test Point 3 | −5.56 | 1.2 | −5.57 | 1.22 |