Table 4:

Summary of reoperations

Age (years)a Interval (years) Aetiology Rheumatic change Patch material Indication Cause of failure Patch calcification Procedure Concomitant surgery
1 34 0.9 Organic Yes CorMatrix MR Patch dehiscence None Replacement
2 65 7.8 Organic No CorMatrix MR Patch dehiscence N/A Replacement CABG, AF ablation LAA closure
3 56 0.5 Functional No CorMatrix MR Band dehiscence None Re-repair TV repair
4 71 6.4 Organic Yes CorMatrix MR N/A N/A Replacement
5 78 0.4 Mixed No CorMatrix MR Patch enlargement None Replacement
6 54 3.5 Organic Yes CorMatrix MS Progressive rheumatic disease Calcified Replacement TV repair
7 46 6.9 Functional No Autologous pericardium MR Patch dehiscence Calcified Replacement LAA closure
8 58 6.4 Organic Yes CardioCel MR Patch dehiscence Calcified Replacement TV repair
9 80 0.8 Organic Yes CardioCel MS Progressive rheumatic disease None Replacement
Mean ± SD 60.2 ± 15.0 3.7 ± 3.1
a

At initial operation.

AF: atrial fibrillation; CABG: coronary artery bypass grafting; LAA: left atrium appendage; MR: mitral regurgitation; MS: mitral stenosis; N/A: not available; SD: standard deviation; TV: tricuspid valve.