Table 2. Conductivity Values for Compounds 1–3 Measured at Low and High Temperatures in 95% Relative Humidity and in Dry Nitrogen.

  σ (S cm–1) at low temperaturea
σ (S cm–1) at high temperaturea
compound 95% RH dry N2 95% RH dry N2
1 d7.05 × 10–6 b f1.16 × 10–4 f8.49 × 10–9
2 b1.1 × 10–5 c4.5 × 10–9 f1.85 × 10–4 e1.43 × 10–7
3 b5.26 × 10–5 d4 × 10–9 f1.87 × 10–3 f1.05 × 10–7
a

T stabilized value of the measurements.

b

25 °C.

c

27 °C.

d

30 °C.

e

75 °C.

f

80 °C.