Skip to main content
. 2022 Aug 15;12:13814. doi: 10.1038/s41598-022-17873-x

Table 2.

MRS data quality parameters.

Baseline assessment Lovastatin Placebo
Mean (S.E.) Range Mean (S.E.) Range Mean (S.E.) Range
HERMES
Fit Error (%) 6.30 (0.45) 3.31–8.15 6.77 (0.42) 4.13–8.91 7.36 (0.55) 4.86–9.68
FWHM (Hz) 10.43 (0.67) 8.97–15.50 10.00 (0.46) 7.69–12.57 9.52 (0.46) 7.87–13.24
SNR 10.05 (0.75) 7.15–15.09 8.52 (0.61) 5.36–10.76 8.05 (0.49) 6.04–10.06
PRESS
CRLB (%) 7.18 (0.263) 6–9 7.62 (0.21) 7–9 7.42 (0.23) 6–9
FWHM (Hz) 6.39 (0.53) 4.22–9.71 5.94 (0.36) 4.22–8.56 5.88 (0.50) 4.22–10.99
SNR 40 (2.59) 30–58 40.46 (1.54) 34–50 35.42 (1.68) 28–49

S.E. standard error, FWHM full width at half maximum, SNR signal-to-noise ratio, CRLB Cramér-Rao Lower Bound.