. 2020 Oct 22;69(3):192–199. doi: 10.1111/idj.12456

Table 1.

Bacterial contamination of water samples from air/water syringes and dental handpieces [colony-forming units (CFUs)/mL]

Year Air/water syringes
Dental handpieces
Total
n Range Median (P25–P75) ≤500 n (%) ≤100 n (%) n Range Median (P25–P75) ≤500 n (%) ≤100 n (%) n Range Median (P25–P75) ≤500 n (%) ≤100 n (%)
2012 24 2–30,000 970 (71.5–2,562.5) 11 (45.83) 10 (41.67) 0 24 2–30,000 970 (71.5–2,562.5) 11 (45.83) 10 (41.67)
2013 99 0–267,120 158 (33–1,360) 53 (53.54) 52 (52.53) 99 1–718,680 406 (100–11,200) 46 (46.46) 43 (43.43) 198 0–718,680 249.5 (55.25–3,000) 99 (50) 95 (47.98)
2014 58 0–1,700,000 125 (8.5–2,775) 38 (65.52) 31 (53.45) 58 0–1,800,000 390 (35.5–9,375) 36 (62.07) 32 (55.17) 116 0–1,800,000 235 (14.25–5,975) 74 (63.79) 63 (54.31)
2015 42 0–620,000 350 (73.5–1,375) 28 (66.67) 27 (64.29) 41 0–550,000 430 (140–2,500) 23 (56.10) 20 (48.78) 83 0–620,000 400 (98–1,600) 51 (61.45) 47 (56.63)
2016 50 0–66,000 180 (4–1,975) 26 (52.00) 24 (48.00) 50 0–64,000 370 (20.75–3,650) 27 (54.00) 19 (38.00) 100 0–66,000 290 (14.25–2,200) 53 (53) 43 (43.00)
2017 45 0–32,000 120 (26–1,600) 30 (66.67) 21 (46.67) 45 0–64,000 450 (91.5–2,950) 25 (55.56) 12 (26.67) 90 0–64,000 230 (35–1,925) 55 (61.11) 33 (36.67)
Total 318 0–1,700,000 190 (27.75–1,825) 186 (58.49) 165 (51.89) 293 0–1,800,000 410 (66.5–4,100) 157 (53.58) 126 (43.00) 611 0–1,800,000 280 (35–2,450) 343 (56.14) 291 (47.63)