Table 2. Accuracy and precision of ceftriaxone in different anticoagulants.

The method was validated by analysing five replicate samples of each concentration and repeated over four days. Accuracy and precision must not exceed 15% for each concentration. However, accuracy is not reported since the QC samples were compared against a calibration curve using CPD plasma and the recovery difference would bias the accuracy result.

Anticoagulant Nominal
conc. (μg/ml)
Intra-assay
precision (%RSD)
Inter-assay
precision (%RSD)
Total-assay
precision (%RSD)
EDTA, QC 1 2.97 5.52 5.56 5.54
Na-Heparin, QC 1 2.97 7.53 13.5 8.75
Li-Heparin, QC 1 2.97 7.35 9.00 7.64
EDTA, QC 3 155 3.81 4.76 3.98
Na-Heparin, QC 3 155 4.10 10.5 5.62
Li-Heparin, QC 3 155 3.77 5.40 4.07

QC, Quality Control; RSD, Relative Standard Deviation.