Table E4.
Study | Isolated SAVR, n | Concomitant procedures, n |
Mitral repair/replacement, n | CABG, n | Tricuspid repair/replacement, n | Implanted valve type, n |
CPB time, min, mean ± SD | Aortic cross-clamp time, min, mean ± SD | |||
---|---|---|---|---|---|---|---|---|---|---|---|
Aortic repair | Aortic root repair | Ascending aortic repair | Bioprosthesis | Mechanical prosthesis | |||||||
Mangner et al, 20188 | 6 | 9 | 6 | 3 | 7 | 3 | N/A | N/A | N/A | N/A | N/A |
Jawitz et al, 20209∗ | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Nakazato et al, 202010 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Hirji et al, 202011 | 198 | 0 | 0 | 0 | N/A | 19 | N/A | N/A | N/A | N/A | N/A |
Tang et al, 202012 | 147 | 61 | 43 | 18 | 58 | 36 | 24 | 224 | 43 | 150.9 ± 72.4 | 109.4 ± 57.0 |
Fukuhara et al, 202113† | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Brescia et al, 202114‡ | 6 | 10 | 4 | 8 | 4 | 5 | 2 | 19 | 2 | 177 ± 69 | 133 ± 50 |
Fukuhara et al, 202115 | 345 | 200 | 152 | 97 | 165 | 122 | 46 | 710 | 72 | 168 ± 79 | 117 ± 57 |
Malvindi et al, 202116 | 7 | 6 | 5 | 4 | 5 | 2 | 0 | N/A | N/A | N/A | N/A |
Fukuhara et al, 202117§ | 53 | 53 | 43 | 27 | 42 | 32 | 16 | 124 | 17 | 162.3 ± 83.4 | 113.6 ± 51.6 |
SAVR, Surgical aortic valve replacement; CABG, coronary artery bypass grafting; CPB, cardiopulmonary bypass; SD, standard deviation; N/A, not applicable.
All data were excluded owing to potential duplication with reference 15.
All data were excluded owing to potential duplication with reference 15.
Data between 2016 and 2018 were excluded owing to duplication with reference 15.