Skip to main content
. 2022 Aug 23;11:32. doi: 10.1186/s13741-022-00263-2

Table 4.

Functional assessment at baseline and post-exercise intervention

Outcome measures Baseline Post-intervention Mean difference 95% Confidence interval
CPET
 AT (ml/kg/min) 9.7 (1.6) 10.6 (1.8) 0.9 0.3, 1.5
 Peak VO2 (ml/kg/min) 13.8 (3.0) 14.7 (3.0) 0.8 0.2, 1.4
 Peak VO2/BSA (mLs/kg) 581 (127.5) 625 (143.6) 43.6 11.6, 75.6
Sit-to-stand (repetitions) 12 (4) 12 (4) 0 1, 2
n Mean 95% Confidence interval
6MWD (m)
 Baseline 43 451 418.6, 482.3
 Post-intervention 43 471 437.8, 503.3
 30 days postoperative 28 349 308.1, 390.7
Handgrip strength (kg)
 Baseline 43 34 30.3, 36.9
 Post-intervention 43 35 31.4, 38.1
 30 days postoperative 29 31 27.0, 34.8

Data are presented as mean (standard deviation). Paired sample t test used for CPET variables (n=42) and sit-to-stand (n=27) variables and linear mixed models used for 6MWD (n=43) and handgrip strength (n=43). Abbreviations: 6MWD 6-min walk distance, CPET cardiopulmonary exercise test, AT anaerobic threshold, VO2 peak volume of O2 consumed at peak exercise, BSA body surface area