Table 4.

Percentage error between visually counted steps and steps from each monitor.

Device % Error, mean (95% CI)a % Error, minimum, maximum (range) ≥ 5% Error, n (%) ≥10% Error, n (%) ≥25% Error, n (%)
Fitbit Alta −80.6 (−113.0, −48.3) −216.7, 48.3
(265.0)
19 (100) 18 (95) 18 (95)
Fitbit Zip −14.9 (−47.0, 17.2) −151.6, 82.8
(234.4)
17 (89) 14 (74) 8 (42)
Garmin Vivofit 4 −67.6 (−90.9, −44.2) −168.4, 28.8
(197.2)
18 (95) 18 (95) 16 (84)
Yamax SW200 12.1 (−5.2, 29.4) −79.5, 93.7
(173.2)
16 (84) 13 (68) 7 (37)
Letscom −112.3 (−148,8, −75.9) −318.8, 32.7
(351.5)
19 (100) 19 (100) 18 (95)
activPAL3μb 59.0 (56.6, 61.3) 54.2, 70.3
(16.1)
19 (100) 19 (100) 19 (100)
a

Positive value indicates the device underestimates steps in comparison to manual count.

b

n = 16.