Table 4.

Lesion features according to their detectability in original PET90 and denoised PET45AI

Size on CT (mm) MV (ml) 1 SULmax (g/ml)
Absolute detection Long axis Short axis
  Concordant 16 [10–24] 10 [7–16] 1.3 [0.6–3.2] 4.4 [3.1–7.5] (2)
  Discordant PET90 only 5 [5–6] 4 [3–6] 0.8 [0.6–1.2] 2.1 [1.5–2.6]
  Discordant PET45AI only NA3 NA 1.2 [0.6–2.9] 3.0 [2.5–3.3]
Preferred serie for detection
  No 17 [11–25] 11 [7–17] 1.5 [0.8–3.8] 4.6 [3.1–7.7] (2)
  PET90 9 [7–12] 7 [5–9] 1.1 [0.7–1.8] 2.7 [2.0–3.6] (2)
  PET45AI 8 [5–22] 6 [4–16] 1.5 [0.9–2.7] 2.2 [1.6–2.8] (2)

All measures are displayed as median [interquartile range]; 1 MV, metabolic volume. Note that metabolic volumes of small lesions and with low contrast-to-background ratios are less accurate. 2 of original PET90; 3 NA, not assessable (no measurable CT lesion)