Evaluation metrics for test set using RF classification in the first ten PCs.

Minimum 1st Quantile Median Mean 3rd Quantile Maximum
Accuracy 0.8654 0.9519 0.9615 0.9624 0.9808 1.0000
Sensitivity 0.7500 0.9038 0.9423 0.9338 0.9615 1.0000
Specificity 0.8846 0.9808 1.0000 0.9910 1.0000 1.0000

Accuracy, sensitivity, and specificity are reported across 5000 runs.