Table 3.
Operating conditions of the absorption–desorption process based on the non-dispersive gas–liquid HFMC contactors, laboratory scale.
| Parameter/Property | Value | Unit |
|---|---|---|
| Volume, V | 250 | mL |
| Temperature, T | 289–310 | K |
| Feed Gas flow rate, Fg | 60 | mL·min−1 |
| Liquid flow rate, Fl | 60 | mL·min−1 |
| Feed gas pressure, Pg,in | 1.03 | bar |
| Liquid pressure, Pl,in | 1.31 | bar |
| Vacuum pressure, Pv | 0.04–0.50 | bar |