Skip to main content
. 2020 Dec 8;87(3):353–365. doi: 10.1016/j.bjorl.2020.11.006

Table 5.

Meta-analysis estimates of cochlear implantation on the Tinnitus Handicap Inventory score. The mean summary difference across the studies indicated an 11.66-point reduction in the tinnitus severity score (95% CI 5.67 to 17.65; p < 0.001). There was marked heterogeneity between the studies (I2 = 96.4%).

Study Mean differences 95% CI Weight (%)
1. Arts R.A. et al. 12.50 8.16; 16.84 13.87
2. Arts R.A. et al. 17.10 13.17; 21.03 14.06
3. Dillon M.T. et al. 18.15 16.11; 20.19 14.71
4. Ramakers G.G.J. et al. 1 -3.07 -6.07; -0.06 14.42
5. Ramakers G.G.J. et al. 2 6.44 4.07; 8.82 14.62
6. Di Nardo W. et al. 19.50 14.99; 24.01 13.79
7. van Zon A. et al. 11.46 8.77; 14.15 14.53
Global 11.66 5.67; 17.65 100.00

Heterogeneity (p-value < 0.001); I2 = 96.4% of variation (randomized); global means test (p-value ≤ 0.001).