Skip to main content
. 2022 Jun 16;43(33):3118–3128. doi: 10.1093/eurheartj/ehac286

Table 3.

Diagnostic performance of single-photon emission computed tomography, positron emission tomography, and magnetic resonance imaging for the detection of coronary artery disease when referenced by a fractional flow reserve threshold of <0.75 on a per-patient level

% (95% CI)
SPECT PET MRI
Sensitivity 76 (66–84) 92 (85–97) 77 (67–86)
Specificity 62 (52–72) 65 (54–74) 66 (55–75)
PPV 67 (60–73) 73 (66–78) 68 (61–75)
NPV 73 (64–80) 90 (81–95) 75 (66–82)
Accuracy 69 (62–76) 79 (72–84) 71 (64–78)
AUC 0.73 (0.66–0.80) 0.88 (0.83–0.93) 0.73 (0.66–0.80)

AUC, area under the receiver operating characteristic curve; CI, confidence interval; MRI, magnetic resonance imaging; NPV, negative predictive value; PET, positron emission tomography; PPV, positive predictive value; and SPECT, single-photon emission computed tomography.