Table 1. Human Assessment of Gradeability of Circumpapillary Optical Coherence Tomography (OCT) Image Qualitya.

Variable No. of images Image quality, No. (%)
Clinical expert 1 Clinical expert 2
All 200 184 (92.0) 186 (93.0)
Real 100 88 (88.0) 90 (90.0)
Normal 50 49 (98.0) 46 (92.0)
Glaucoma 50 39 (78.0) 44 (88.0)
Synthetic 100 96 (96.0) 96 (96.0)
Normal 50 50 (100.0) 50 (100.0)
Glaucoma 50 46 (92.0) 46 (92.0)
a

To avoid any evaluation bias, image type (real glaucoma/real normal/synthetic glaucoma/synthetic normal) of the 200 images was not revealed to either of the clinicians. Image quality of each of the 200 images was graded by both clinicians. Values indicate the number (%) of images graded as good quality.