Table 7.

Differential dose (cGy) distribution from unilateral radiation exposure.

Radiation Source Exposure aspect Entrance dose (cGy) Exit dose (cGy) Mid dose (cGy) Source/Authors
fission neutron bilateral 263 263 263 Ainsworth et al. 1965
fission neutron unilateral 455 121 299 Ainsworth et al. 1965
1.9 Mev neutron unilateral 420 280 --- Wang et al. 1991
1 Mvp x-ray unilateral 631 237 453 Ainsworth et al. 1965

All studies were published in the open literature or in government publications. The studies were conducted to provide a dose response relationship for the H-ARS and threshold GI-ARS mortality. All dose rates were steady state. Depth dose dosimetry provided air dose (cGy) at surface, midline and exit (surface).