Skip to main content
. 2022 Sep 2;17(9):e0271315. doi: 10.1371/journal.pone.0271315

Table 1. The frequency of trips/stumbles by prosthesis type and each of the covariates.

Odds ratios (OR) and 95% Confidence Intervals (CI) are shown; bold text indicates statistically significant observations.

None (n = 134) 1–5 times (n = 145) More than 5 times (n = 36) OR 95% CI
Prosthesis type
Below knee prosthesis users 84 78 16 1.00
Non-microprocessor knee users 32 53 18 1.96 1.17–3.28
Microprocessor knee users 18 14 2 0.74 0.33–1.64
Covariates
Sociodemographic
Sex
Male 108 118 27 1.00
Female 26 27 9 1.03 0.58–1.83
Age
18–39 years 21 23 3 1.00
40–59 years 48 66 15 0.99 0.50–1.96
60–79 years 61 50 18 0.80 0.40–1.64
>80 years 4 6 0 0.65 0.17–2.48
Experience
Years of prosthesis use
>10 years 94 90 24 1.00
6–10 years 16 19 3 1.01 0.50–2.05
1–5 years 14 32 8 1.62 0.85–3.07
<1 year 10 4 1 0.43 0.13–1.40
Health
Comorbidity (-ies)
No 106 115 28 1.00
Yes 28 30 8 0.89 0.50–1.57
Contralateral limb injury
No 107 101 21 1.00
Yes 27 44 15 1.91 1.15–3.18
Medication
No 125 128 32 1.00
Yes 9 17 4 1.16 0.55–2.45
Physical function
Walking aid(s)
No 79 66 12 1.00
Yes 55 79 24 1.99 1.13–3.50
Activity level
K2 58 75 18 1.00
K3 63 56 14 1.28 0.72–2.29
K4 13 14 4 1.53 0.64–3.68