Table 3.
Diagnostic accuracy characteristics (AUC, sensitivity, specificity and accuracy) for GSH concentrations, susceptibility, and the combined effect of GSH concentration and susceptibility levels to differentiate among the three groups (HO, MCI and Alzheimer’s disease)
Parameter | AUC | S.E. | P-value | Sensitivity | Specificity | PPV | NPV | Accuracy |
---|---|---|---|---|---|---|---|---|
HO versus MCI | ||||||||
GSH conc. | 0.738 | 0.086 | 0.017* | 0.720 | 0.692 | 0.785 | 0.612 | 0.709 |
Susceptibility | 0.551 | 0.104 | 0.595 | 0.636 | 0.688 | 0.761 | 0.547 | 0.656 |
GSH + susceptibility | 0.741 | 0.085 | 0.018* | 0.692 | 0.682 | 0.582 | 0.776 | 0.686 |
HO versus Alzheimer’s disease | ||||||||
GSH conc. | 0.868 | 0.049 | 0.000* | 0.760 | 0.846 | 0.799 | 0.814 | 0.808 |
Susceptibility | 0.744 | 0.075 | 0.006* | 0.682 | 0.682 | 0.727 | 0.633 | 0.682 |
GSH + Susceptibility | 0.856 | 0.062 | 0.000* | 0.818 | 0.824 | 0.789 | 0.849 | 0.821 |
MCI versus Alzheimer’s disease | ||||||||
GSH Conc. | 0.675 | 0.091 | 0.079 | 0.615 | 0.692 | 0.507 | 0.777 | 0.666 |
Susceptibility | 0.722 | 0.091 | 0.021* | 0.864 | 0.688 | 0.843 | 0.723 | 0.804 |
GSH + susceptibility | 0.751 | 0.090 | 0.020* | 0.769 | 0.765 | 0.628 | 0.865 | 0.766 |
*All significant values are set to P < 0.05.