Table 2:

Summary of motion management and image guidance utilized in Adrenal SBRT studies at the time of simulation, planning, and treatment.

Author (citation) Motion Management: Simulation and Planning Motion management: Image Guidance for Treatment
Ahmed, 2013 (7) 4DCT/ITV ^Daily CB (2nd confirming CB for shifts> 3 mm)
Barney, 2012 (8) Compression for diaphragm motion ≥ 5 mm + 4DCT to construct ITV ^Daily CB (2nd confirming CB for shifts > 3 mm)
Casamassima, 2012 (9) ITV from free-breathing, end inhale and end exhale CT scans at simulation Daily CB (matched on bone)
Chawla, 2009 (5) End Exhale Breath-hold NR
Guiou, 2012 (10) Compression if tolerated (5/9 pts); 4DCT for ITV Daily CB
Holy, 2011 (11) Compression (14/18 pts): SI margins from fluoroscopy of diaphragm Daily orthogonal radiographs compared to DRR
Katoh, 2008 (12) One implanted fiducial; Planning CT at end-exhale. RTRT fluoroscopic tracking system, tracking fiducial
Oshiro, 2011 (27) End exhale gating (9/11 pts) Gating with modified Microtron
Rudra, 2011 (13) Simulation with free-breathing, 4DCT and end exhale scans; plan for ITV (‘not significant tumor motion’) or end exhale Daily orthogonal radiographs (match on bone) followed by ungated CB to verify PTV margin
Scorsetti, 2012 (14) Population based Orthogonal KV radiographs (2D-2D)
Torok, 2011 (15) 4DCT for the 2/7 gating patients 5/7 pts CK (Synchrony system); 2/7 pts Trilogy with gating
Desai, 2015 (22) (single fiducial placed; free-breathing CT; margins NR CK (Synchrony system)
Chance, 2016 (18) 4DCT; ITV for 86% of pts, voluntary deep-inhale breath-hold for tumor motion> 1 cm (14% pts) Daily CB or CT on Rails
Franzese, 2017 (26) Abdominal compression and 4DCT for construction of ITV (union of CTVs on all phases) Daily CB compared to simulation scan
Gamsiz, 2015 (16) Moderate deep inhale using ABC™ device Daily CB
Li, 2013 (23) ≥ 3 fiducials placed; generic margins CK

Abbreviations: ITV (internal target volume); CB (cone beam); NR (not reported); DRR (digitally reconstructed radiograph); KV (kilovoltage); CK (CyberKnife);RTRT (Real-time Tumor-tracking radiotherapy (40)

^

matching structure not stated