Skip to main content
. 2022 Sep 5;10(9):23259671221121352. doi: 10.1177/23259671221121352

Table 4.

Comparison of hip Joint Kinematic and Kinetic Variables During Gait Between Baseline and 1 Year Postoperatively a

Baseline 1-y Postop P
Peak joint angle, deg
 Flexion 21.5 ± 7.9 24.0 ± 5.9 .30
 Extension −17.0 ± 7.1 −15.5 ± 6.4 .27
 Adduction 7.8 ± 2.5 6.4 ± 2.5 .062
 Abduction −2.3 ± 1.8 −4.6 ± 1.8 .0058
 IR 5.5 ± 5.8 4.6 ± 5.8 .62
 ER −5.5 ± 6.5 −8.9 ± 3.4 .0504
Peak joint moment, N·m/kg
 Flexion 0.59 ± 0.16 0.66 ± 0.13 .32
 Extension −1.03 ± 0.19 −0.85 ± 0.20 .014
 Adduction 0.10 ± 0.05 0.08 ± 0.05 .43
 Abduction −1.04 ± 0.21 −1.00 ± 0.11 .46
 IR 0.13 ± 0.07 0.14 ± 0.08 .92
 ER −0.17 ± 0.08 −0.16 ± 0.06 .84

a Boldface P values indicate statistically significant difference (P < .05, paired t test). ER, external rotation; IR, internal rotation; Postop, postoperatively.