Skip to main content
. 2021 Oct 29;60(4):371–386. doi: 10.2486/indhealth.2021-0114

Table A.3. Personal measurements–concentration of respirable fraction and comparison with the exposure reference limits.

Metal Printer Printing process Median
[μg/m3]
Ranges of measured values
[μg/m3]
Exposure reference limits [μg/m3] Ratio Max value/Reference limits [%]
Cr PV_SLM SLM 0.038 0.007–0.068 ACGIH=500
OSHA=1,000
NIOSH=500
0.007–0.014
MI_SLM SLM 0.091 0.034–0.149 0.010–0.030
MI_LMD LMD 0.021 0.014–0.114 0.011–0.023
NE_SLM/NE_HYB SLM 0.5 0.020–0.180 0.018–0.036

Co PV_SLM SLM 0.206 0.008–0.404 ACGIH=20
OSHA=100
NIOSH=50
0.404–2.020
MI_SLM SLM 0.117 0.087–0.147 0.147–0.735
MI_LMD LMD 0.043 0.031–0.260 0.520–1.30
NE_SLM/NE_HYB SLM 0.039 0.014–0.064 0.064–0.32

Ni PV_SLM SLM 0.013 0.010–0.015 ACGIH=1,500
OSHA=1,000
0.001–0.002
MI_SLM SLM 0.639 0.443–0.836 0.056–0.084
MI_LMD LMD 0.466 0.190–1.129 0.075–0.113
NE_SLM/NE_HYB SLM 0.179 0.012–0.201 0.013–0.020

Fe PV_SLM SLM 0.431 0.050–0.813 No limits available
MI_SLM SLM 0.016 0.015–0.018
MI_LMD LMD 0.009 0.006–0.050
NE_SLM/NE_HYB SLM 0.3 0.015–0.444

Cu1 NE_SLM/NE_HYB SLM 0.041 0.003–0.159 ACGIH=1,000
OSHA=1,000
NIOSH=1,000
0.016