Skip to main content
. 2022 Aug 26;23(17):9678. doi: 10.3390/ijms23179678

Table 5.

Analyses of variance analysis of Pb(II) removal.

Source Sum of Squares Degree of Freedom Mean Square F-Value p-Value Status
Model 4650.23 14 332.16 129.71 <0.0001 Significant
A:pH 3072.00 1 3072.00 1199.64 <0.0001
B: Adsorbent dose 275.52 1 275.52 107.59 <0.0001
C: Contact time 0.0208 1 0.0208 112.36 <0.0001
D: Temperature 300.00 1 300.00 117.15 <0.0001
A.B 243.23 1 243.23 20.12 0.0021
A.C 123.12 1 123.12 30.45 0.0034
A.D 110.23 1 110.23 42.56 0.0043
B.C 0.0625 1 0.0625 0.0244 0.8785
B.D 4.00 1 4.00 10.56 0.0232
C.D 0.0024 1 0.0024 0.0120 1.0000
A2 886.95 1 886.95 346.36 0.0523
B2 94.45 1 94.45 36.88 0.8412
C2 3.70 1 3.70 1.45 0.02523
D2 8.61 1 8.61 3.36 0.0916
Residual 30.73 12 2.56 - -
Lack of Fit 30.73 10 3.07 4.52 0.86 Not significant
Pure Error 0.0024 2 0.0049 - -
Cor Total 4680.96 26 - - -

R2 = 0.99, R2adjusted = 0.98. Adequate Precision = 37.50.