Skip to main content
. 2022 Sep 8;9:551. doi: 10.1038/s41597-022-01656-0

Table 2.

Scanning strategy configuration for all elevations of the BoXPol scan for Enigma 3 and Enigma 4.

Elevation [°] 2014-01-01 - 2017-04-03 2017-04-04 - 2019-06-30
Range [km] Enigma 3 PRF [Hz] Range [km] Enigma 4 PRF [Hz]
Resolution [m] Resolution [m]
1.0 150 150 400 150 200 700
1.5 100 100 950
2.0 150 200 800
2.4 100 100 1000
3.1 150 200 900
4.5 100 150 950 150 200 950
6.0 140 150 1050
7.0 50 25 1000
8.2 110 100 1150 100 125 1150
11.0 100 100 1150 80 125 1150
14.0 80 100 1150 62 125 1150
18.0 55 100 1150 50 125 1150
28.0 35 100 1150 36 125 1150