Skip to main content
. 2022 Aug 31;22(17):6582. doi: 10.3390/s22176582

Table A4.

Shock wave parameters of a moving charge explosion experiment (V = 717 m/s, x = +1 m).

No. Distance (m) Direction (°) Overpressure (MPa) Arrival Time (ms) Duration (ms) Impulse (Pa·s)
1 5.000 0 0.1241 7.6924 3.4291 171.8705
2 7.000 0 0.108 11.6038 - -
3 5.390 22 0.0645 - - -
4 7.280 16 0.0709 12.3864 5.175 122.4323
5 6.400 39 - - - -
6 8.060 30 - 14.1269 - -
7 7.810 130 - - - -
8 6.710 117 0.0615 13.1714 3.6121 56.5451
9 6.080 99 0.0801 11.6785 - -
10 6.080 81 0.0819 11.0933 - -
11 6.710 63 - - - -
12 7.810 50 0.0497 14.3434 5.2028 96.0351
13 9.220 41 0.0612 17.4136 3.8273 81.3008
14 9.430 122 0.0338 20.8034 4.659 52.8053
15 8.540 111 0.039 18.0594 4.1001 56.2667
16 8.060 97 0.0426 16.1012 4.3131 69.512
17 8.060 83 0.0229 15.1299 3.941 26.9796
18 8.540 69 - - - -
19 9.430 58 0.0555 17.6737 5.4401 74.174
20 10.630 49 0.0499 20.3965 - -