Table 4:

Average relative uncertainty of SPR values simulated with different physics lists and range cut values, calculated by averaging the total relative uncertainty for all eleven samples.

Average Relative Uncertainty of Stopping Power Ratio Values (%)
Range cut value QGSP_FTFP_BERT QGSP_BIC_HP QGSP_BIC QGSP_BERT_HP QGSP_BERT QBBC
0.01 mm 0.127 0.129 0.131 0.125 0.126 0.125
0.1 mm 0.127 0.125 0.126 0.122 0.125 0.138