Table 9.

Percent noise of normalized depth dose curve for different Geant4 physics lists with range cut values as 0.1 mm.

Insert Geant4 physics lists results
QGSP_FTFP_BERT QGSP_BIC_HP QGSP_BIC QGSP_BERT_HP QGSP_BERT QBBC
K2HPO4_1 0.38 0.51 0.43 0.46 0.42 0.36
K2HPO4_2 0.36 0.31 0.30 0.36 0.37 0.32
K2HPO4_3 0.33 0.30 0.30 0.33 0.33 0.31
K2HPO4_4 0.32 0.28 0.29 0.33 0.35 0.34
Ethanol 0.47 0.44 0.52 0.52 0.51 0.49
Propanol 0.50 0.45 0.50 0.51 0.47 0.44
Butanol 0.44 0.44 0.43 0.49 0.48 0.42
Acrylic 0.39 0.25 0.42 0.25 0.39 0.42
HDPE 0.36 0.34 0.41 0.43 0.43 0.37
Delrin 0.31 0.25 0.30 0.29 0.29 0.27
PTFE 0.22 0.20 0.22 0.22 0.23 0.22