Skip to main content
. 2022 Sep 10;12:15282. doi: 10.1038/s41598-022-19498-6

Table 2.

Objective settings for optimization with the big model and each single-institution model.

Institution Organ Objective Volume Dose gEUD Priority Objective Volume Dose Priority
A Rectum Upper 0% 100% Generate CTV Upper 0% 104% Generate
Line Generate Lower 100% 100% Generate
Bladder Upper 0% 100% Generate PTV Upper 0% 104% Generate
Line Generate Lower 100% 90% Generate
B Rectum wall Line Generate PTV Upper 0% 102% 120
Bladder wall Line Generated Lower 100% 99% 120
C Rectum Upper 0% 100% 0 PTV Upper 0% 100% 115
Upper gEUD 69.2% 9 Generate Lower 100% 93.0% Generate
Line Generate Lower 97% 96.0% Generate
Bladder Line Generate Lower 95.50% 98.0% Generate
Lower 90% 100.0% Generate
D Rectum Upper 0% 76.9% 85 CTV Upper 0% 100.0% Generate
Line Generate Lower 95% 97% Generate
Bladder Upper 0% 79.5% 75 Lower 100% 94.9% Generate
Line Generate PTV Upper 0% 94.9% Generate
E Rectum Upper 0% 99% Generate CTV Upper 0% 102.6% Generate
Upper gEUD 76.9% 10 Generate Lower 100% 99% Generate
Line Generate PTV Upper 0% 103% Generate
Bladder Line Generate Lower 100% 90% Generate
Lower 96% 96% Generate

gEUD Generalized equivalent uniform dose; CTV Clinical target volume; PTV Planning target volume.