Various observations made for the metal acrylic, metal-ceramic type of implant prosthesis

Parameter Findings P

MA MC
Gender (male: female) 1:2 1:2 NS
Mean age 62±9.8 62±8.6 NS
Mean follow-up (months) 57±2.5 53±2.5 NS
Survival rate (1-10 years) (%) 89 72 NS
Mean 5.2 5.1
With complications (%) 85 89 NS
Complication free (%) 15 11 NS
Failed 5 6 NS
Minor complications
 Minor wear of the prosthetic material 14 13
 Minor chipping of veneering material 20 18 0.001
 Loss of access hole material 16 14 0.02
 Fracture of prosthetic material 6 5
 Screw loosening 18 16
 Wear of prosthetic screw 12 10
 Decementation 4 3
Major complications 21 20
 Major wear of prosthetic material 15 14
 Major chipping of veneering material 6 4
 Framework fracture 40 31 0.001
 Abutment fracture 3 1
Patient satisfaction (%) 64 78 NS

NS: Not significant, MA: Metal acrylic, MC: Metal ceramic