Table 2.
Planning accuracy and deviation of implants in absolute values and percentage
| Cup size | Stem size | |||
|---|---|---|---|---|
| Occurrence | Percentage | Occurrence | Percentage | |
| Implant size in general | ||||
| Exact match | 315 | 51 | 320 | 52 |
| ± 1 size | 208 | 34 | 256 | 38 |
| ± 2 sizes | 66 | 11 | 35 | 7 |
| ± 3 sizes or more | 31 | 5 | 9 | 3 |
| Implant size Stryker | ||||
| Exact match | 267 | 49 | 288 | 53 |
| ± 1 size | 187 | 35 | 202 | 38 |
| ± 2 sizes | 60 | 11 | 35 | 7 |
| ± 3 sizes or more | 30 | 5 | 15 | 3 |
| Implant size DePuy Synthes | ||||
| Exact match | 48 | 63 | 32 | 42 |
| ± 1 size | 21 | 28 | 33 | 43 |
| ± 2 sizes | 6 | 8 | 10 | 13 |
| ± 3 sizes or more | 1 | 1 | 1 | 1 |
| Accurate acetabular planning | Accurate femoral planning | |||
|---|---|---|---|---|
| Planner’s experience | ||||
| EndoCert-certified surgeon | 150 | 90 | 150 | 90 |
| Non-EndoCert-certified surgeon | 79 | 85 | 80 | 86 |
| Sex | ||||
| Female | 264 | 83 | 295 | 94 |
| Male | 259 | 86 | 260 | 86 |
| Preoperative diagnosis | ||||
| Primary osteoarthritis | 448 | 84 | 475 | 89 |
| Protrusion osteoarthritis | 11 | 92 | 12 | 100 |
| Femoral head necrosis | 50 | 93 | 50 | 93 |
| Hip dysplasia | 14 | 74 | 18 | 90 |
Deviation of one size is considered to be accurate