Table 4.

Inter- and intra-reliability results between-system, -limb and -device

Gait conditions Inter-system reliability Inter-limb reliability Test–retest intra-device reliability
ICC¥ 95% CI ICC¥ 95% CI ICC¥ 95% CI
Pooled gait conditions
Double limb stance time 0.96 0.94, 0.97 0.99 0.99, 0.99 0.98 0.97, 0.98
Single limb stance time 0.99 0.99, 0.99 0.99 0.98, 0.99 0.98 0.97, 0.98
Step length 0.90 0.84, 0.93 0.94 0.91, 0.96 0.97 0.96, 0.98
Cadence 0.99 0.99, 0.99 0.99 0.99, 0.99 0.98 0.97, 0.98
Stride length 0.93 0.89, 0.95 0.96 0.93, 0.97 0.96 0.94, 0.97
Swing time 0.95 0.92, 0.96 0.93 0.90, 0.95 0.94 0.86, 0.97
Gait speed 0.96 0.94, 0.97 0.99 0.99, 0.99 0.98 0.97, 0.99
Self-selected gait speed
Double limb stance time 0.61 0.25, 0.82 0.82 0.59, 0.92 0.90 0.77, 0.95
Single limb stance time 0.95 0.87, 0.97 0.94 0.85, 0.97 0.91 0.79, 0.96
Step length 0.60 0.23, 0.82 0.72 0.40, 0.87 0.81 0.57, 0.91
Cadence 0.99 0.99, 0.99 0.99 0.99, 0.99 0.93 0.83, 0.97
Stride length 0.79 0.53, 0.91 0.82 0.60, 0.92 0.83 0.62, 0.92
Swing time 0.83 0.62, 0.92 0.80 0.57, 0.91 0.90 0.76, 0.95
Gait speed 0.89 0.73, 0.95 0.90 0.77, 0.96 0.92 0.80, 0.96
Fixed gait speed 0.8 m/s
Double limb stance time 0.82 0.60, 0.92 0.91 0.79, 0.96 0.88 0.72, 0.94
Single limb stance time 0.97 0.92, 0.98 0.94 0.85, 0.97 0.80 0.56, 0.91
Step length 0.56 0.18, 0.80 0.72 0.42, 0.88 0.88 0.72, 0.94
Cadence 0.99 0.99, 0.99 0.99 0.99, 0.99 0.80 0.57, 0.91
Stride length 0.79 0.54, 0.91 0.86 0.67, 0.94 0.88 0.72, 0.95
Swing time 0.92 0.80, 0.96 0.74 0.45, 0.88 0.74 0.46, 0.88
Gait speed 0.76 40, 0.90 0.70 0.38, 0.86 0.61 0.24, 0.82
Fixed gait speed 2.0 m/s
Double limb stance time 0.63 0.27, 0.83 0.72 0.42, 0.88 0.78 0.53, 0.90
Single limb stance time 0.97 0.91, 0.98 0.99 0.97, 0.99 0.86 0.68, 0.94
Step length 0.62 0.04, 0.85 0.71 0.39, 0.87 0.85 0.66, 0.93
Cadence 0.99 0.99, 0.99 0.99 0.99, 0.99 0.89 0.74, 0.95
Stride length 0.79 0.54, 0.91 0.85 0.66, 0.93 0.72 0.41, 0.87
Swing time 0.91 0.79, 0.96 0.97 0.92, 0.98 0.91 0.79, 0.96
Gait speed 0.63 0.27, 0.83 0.62 0.26, 0.83 0.83 0.62, 0.92
Self-selected gait speed and dual task
Double limb stance time 0.82 0.60, 0.92 0.73 0.44, 0.88 0.93 0.84, 0.97
Single limb stance time 0.96 0.89, 0.98 0.95 0.88, 0.98 0.96 0.91, 0.98
Step length 0.62 0.25, 0.83 0.82 0.59, 0.92 0.93 0.84, 0.97
Cadence 0.99 0.99, 0.99 0.99 0.99, 0.99 0.98 0.95, 0.99
Stride length 0.76 0.48, 0.89 0.76 0.49, 0.89 0.97 0.92, 0.98
Swing time 0.84 0.63, 0.93 0.77 0.50, 0.90 0.93 0.84, 0.97
Gait speed 0.87 0.70, 0.94 0.86 0.67, 0.94 0.98 0.96, 0.99

Intraclass correlation coefficient (ICC); confidence interval (CI). Inter-device reliability was measured between motion capture system (Vicon) and smartphone application (OneStep). Inter-limb reliability was measured between smartphone application device secured onto the left and right limbs. Test–retest intra-device reliability was measured between the smartphone application device on the right thigh between time 1 and time 2

¥< 0.50, poor reliability; 0.50–0.75, moderate reliability; 0.75–0.90, good reliability; > 0.90, excellent reliability