Skip to main content
. 2020 Oct 16;88(5):675–682. doi: 10.1016/j.bjorl.2020.09.006

Table 2.

Mean gain, standard deviation, variance, skewness and kurtosis of the vestibulo-ocular reflex obtained in the semicircular canals tested in the different groups with the video head impulse test.

Anterior SCC Lateral SCC Posterior SCC
Controls Mean 0.91 0.95 0.82
Standard deviation 0.06 0.07 0.04
Variance 0.004 0.005 0.002
Skewness −0.261 0.107 0.184
Kurtosis −0.485 0.608 0.256
CNSOM Mean 0.86 0.94 0.78
Standard deviation 0.12 0.08 0.08
Variance 0.015 0.007 0.007
Skewness −0.526a 0.270 0.410
Kurtosis 0.742 −0.324 0.713
CSOM Mean 0.9 0.97 0.82
Standard deviation 0.86 0.11 0.12
Variance 0.015 0.013 0.015
Skewness −1.184b 0.150 −1.452b
Kurtosis 1.670 1.254 3.523
Cholesteatoma Mean 0.82 0.99 0.78
Standard deviation 0.11 0.11 0.12
Variance 0.013 0.013 0.015
Skewness −0.037 −0.248 −0.662a
Kurtosis 0.409 −0.056 1.482

CNSOM, Chronic Non-Suppurative Otitis Media; CSOM, Chronic Suppurative Otitis Media; Cholesteatoma, Cholesteatomatous Chronic Otitis Media; SCC, Semicircular Canal.

a

Moderately skewed distribution value (0.5–1.0).

b

Highly skewed distribution value (> 1.0).